Records: |
| |
Slab On Grade |
|
| |
|
|
| |
Steel Bars Used Shall Be High Steel Deformed Bars O, With A Minimum Proof Stress Of 3600 Kg/Cm2. |
|
| |
|
|
| |
The Final Elevations, Grades, Sequence Of Casting, Panels Dimension And Position Of Joints For Slabs Shall Be Agreed Between Owner And The Contractor |
|
| |
|
|
| |
After Completion Of Excavation & Soil Leveling Works, 20 Cm Thick Crushed Stone Layer Shall Be (If Required In Case Sandstone Layer Does Not Appear) Distributed So That The Surface Of The Sub-Base Shall Have The Required Grades After Compaction. Sub-Grade Shall Be Compacted With Pneumatic Roller Of Sufficient Weight & Smooth Wheel Roller, As Directed By Engineers. Relative Compaction Of Sub-Grade Shall Be 95% According To The Modified AASHTO Designation T180 . |
|
| |
|
|
| |
Concrete Slabs Shall Be Constructed Mostly In Long Lanes. Method Shall Only Be Used Whenever Critical Grades & Panel Dimensions Exists. |
|
| |
|
|
| |
There Are Three Broad Types Of Joints: Expansion Joints, Construction Joints, And Contraction Joints. |
|
| |
|
|
| |
Expansion Joints Are Used To Isolate The Slab From Any Fixed Structure Such As Columns, Curbs, Manholes, Catch Basins, Or Between Slabs. |
|
| |
|
|
| |
Construction Joints Are Stopping Places For A Day’s Work. |
|
| |
|
|
| |
Contraction Joints Are Formed By Saw Cut Every 5m (As Mentioned Above) To Avoid Any Cracks. |
|
| |
|
|
| |
Steel Structure |
|
| |
Tanks: |
|
| |
|
|
| |
Preparation Of Full Engineering For Tanks According To API 650 And API 620 Specifications For Field Welded Tanks And API 12f For Workshop Welded Tanks. |
|
| |
|
|
| |
Supply Of All Kinds Of Steel Materials Grades According To ASTM Standard |
|
| |
|
|
| |
Selection And Supply The Proper Welding Electrodes According To AWS 5.1,5.2 Specification For SMAW Welding Or 5.21,5.24 Specification For GMAW Welding |
|
| |
|
|
| |
Supply Of The Following: |
|
| |
| |
|
 |
Seamless Carbon Steel Pipes For Nozzles |
| |
According To ANSI B 36.10 In Steel Grade ASTM A 106 Gr. B Or According To The Client Specification. |
 |
Class 150 IB. Slip On Raised Face Flanges For |
| |
Nozzles According To ANSI B 16.5 In Steel Grade ASTM A 105 Or According To The Client Specification. |
|
|
| |
|
|
| |
Fabrication Of Tanks According To The Following Breakdown: |
|
| |
| |
|
 |
Tank Plates For Field Erected Tanks Out Of |
| |
Carbon Steel Plates, Includes Cut To Size, Edge Preparation For Site Welding And Delivery To The Site In Loose Segments For Shell , Cover And Flat Or Conical Bottoms According To The Api 650. |
|
|
| |
|
|
| |
Our Scope Of Work Also Includes: |
|
| |
Transportation Up To The Sites. |
|
| |
|
|
| |
Unloading Of Trucks On Site And Erection Of Tanks. Our Erection Works Include The Following Services: |
|
| |
| |
|
 |
Providing Of All Labor For Satisfactory |
| |
Completion Of The Work Within The Project Schedule. |
 |
Providing Of Erection Equipment, Cranes, Tools |
| |
And Auxiliary Material. |
 |
Supply Of Welding Electrodes, Grinding Discs And |
| |
All Other Necessary Consumable. |
|
|
| |
|
|
| |
Execution Of The Following QA/QC Testing On Site After Erection: |
|
| |
| |
|
 |
Radio Graphic Examination Of Butt Welds Of |
| |
Tanks Shell Plates According To The Minimum Requirements Of API 650 Code100. |
 |
Vacuum Test According To API 650 For The |
| |
Welds Of Bottom Plates And Sealed Roofs. |
 |
4hydrostatic Test. |
|
|
| |
|
|
| |
These Tests Will Be Executed According To ASME Sec. |
|
| |
|
|
| |
General. |
|
| |
Intent: |
|
| |
|
|
| |
It Is Intended That This Specification Shall Be Used As A Basis And Guide For The Structural Steelworks Required For This Project. Compliance With The Requirements Herein Specified Does Not Relieve GECO Of His Responsibility To Follow Sound And Accepted Owner Representative Practice Throughout |
|
| |
|
|
| |
Codes: |
|
| |
|
|
| |
In Addition To The Requirements Contained In This Specification All Design, Materials And Workmanship Shall Conform To The Latest Edition Of The Following Codes And Standards: |
|
| |
|
|
| |
 |
AISC |
Specification For The Design, |
| |
|
Fabrication And Erection Of Structural Steel For Buildings. |
 |
AISC |
Specification For Structural Joints |
| |
|
Using ASTM A235 Or A490 Bolts. |
 |
AISC |
Specification For Structural Joints |
| |
|
Using ASTM A235 Or A490 Bolts. |
 |
AWS D1 |
Code For Welding In Building |
| |
|
Construction. |
 |
ASTM 36 |
Structural Steel. |
|
|
| |
|
|
| |
Fabrication. |
|
| |
General: |
|
| |
All Fabrication Shall Be In Accordance With AISC Specification For Design, Fabrication And Erection Of Structural Steel For Buildings And AISC Manual Of Steel Construction. Fabrication Shall Be In Accordance With The Relevant Design And Detail Drawings. Fabrication Shall Commence Only After Detail Drawings Have Been Approved. |
|
| |
|
|
| |
Bolts |
|
| |
All Allowance Of 5% For Wastage Shall Be Made When Supplying Bolts, Nuts And Washers For Site Connections. |
|
| |
|
|
| |
Fabricated Assemblies |
|
| |
All Fabricated Frames Shall Be Suitably Braced To Prevent Distortion During Transit. Frames, Platforms, Stairs, Ladders And Handrails Shall Be Shop Assembled In Largest Units Suitable For Handling And Transportation. |
|
| |
|
|
| |
Member Marks |
|
| |
All Member Marks Shall Be Painted On Members In A Legible Manner In Accordance With The Erection And Detail Drawings. |
|
| |
| |
|
 |
Fabrication. |
 |
Shop And Site Paining. |
 |
Inspection. |
|
|
| |
|
|
| |
Inspection |
|
| |
GECO Shall Supply Mill Test Reports. Owner Representative Reserves The Right To Inspect All Steelworks Prior To Shipment From Fabrication Shop. Approval Of Owner Representative Shall Not In Any Way To Relieve Contractor Of His Responsibility. |
|
| |
|
|
|
| |
|
| |
Records Shall Be Kept By GECO Of The Positions In The Works Of All Batches Of Concrete, Of Their Grade, And Of All Test Cubes Or Other Specimens Taken From Them. |
| |
|
| |
Transport And Placing |
| |
Transport: |
| |
|
| |
The Concrete Shall Be Discharged From The Mixer And Transported To The Works Site . |
| |
|
| |
Placing: |
| |
|
| |
The Concrete Shall Be Placed In Positions And Sequences Indicated On The Drawings, In The Specifications Or As Directed. Concrete Shall Not Be Placed Unless The Client’s Representative Is Present And Has Previously Examined. |
| |
|
| |
Compaction: |
| |
The Concrete Shall Be Fully Compacted Throughout The Full Extent Of The Layer. |
| |
|
| |
Vibration: |
| |
Unless Otherwise Directed By The Client’s Representative Approved Power-Driven Internal Vibrators Shall Be Inserted At Such A Distance Apart Or Applied In Such A Manner As We Ensure That The Concrete Is Satisfactorily And Uniformly Accepted. |
| |
|
| |
Construction Joints: |
| |
|
| |
Concreting Shall Be Carried Out Continuously Up To Construction Joints. |
| |
|
| |
Curing And Protection: |
| |
|
| |
Concrete Shall Be Protected Against The Harmful Effects Of Sunshine, Wind, Temperature,..Etc. |
| |
|
| |
Formwork And Surface Finish: |
| |
General: |
| |
|
| |
Forms Shall Be So Designed And Constructed That The Concrete Can Be Properly Placed And Thoroughly Compacted And That The Hardened Concrete While Still Supported By The Forms Shall Conform Accurately To The Required Shape, Position And Level... GECO Shall Blow Out With Compressed Air Each Day Before Pouring Concrete All Migratory Material That Has Been Deposited Within The Framework And Around The Reinforcement. |
| |
|
| |
Finishing And Tolerances: |
| |
Formwork For Buried Concrete Or For Surface Against Backfill Or Further Concrete Will Be Placed, Shall Be Of Any Suitable Approved Material Which Will Prevent The Loss Of Grout. |
|
| |
|
| |
Striking And Removal Of Forms: |
| |
The Client’s Representative Shall Be Informed In Advance When GECO Intends To Strike Any Formwork. The Forms Shall Be Removed Without Damage To The Concrete. The Use Of Oil Or Other Material To Facilitate This Shall Be Subject To Approval. |
| |
|
| |
Bending And Fixing Reinforcement |
| |
The Bending Of Reinforcement Bars Shall Be In Accordance With The Drawings. The Bars Shall Be Accurately Bent To The Shapes Shown On The Drawings And/Or Bending Schedules. |
| |
|
| |
Foundations And Structures: |
| |
|
| |
Reinforced And Plain Concrete: |
| |
All Reinforced And Plain Concrete Shall Be Designed In Accordance With ACI 318 And Section 3 Of This Specification |
| |
|
| |
Soil Bearing Pressure: |
| |
It Shall Be The Responsibility Of GECO To Determine The Permissible Safe Soil Bearing Pressure From The Soil Investigation Reports. |
| |
|
| |
Chamfers: |
| |
All Corners Of Exposed Concrete Shall Have A 25-Mm Chamfer. |
| |
|
| |
Depth Of Foundations: |
| |
The Underside Of All Foundations Shall Be A Minimum Depth Of 1 M, Or Other Calculated Depth According To Design Basis, Below The Surrounding Grade Level. |
| |
|
| |
Blinding Concrete: |
| |
A Layer Of Blinding Concrete Of 50- Mm Minimum Thickness Shall Be Provided Beneath All Foundations And Below Ground Structures. |
| |
|
| |
Top Of Concrete: |
| |
The Top Of Concrete For Foundations Shall Be A Minimum Of 300 Mm Above The Surrounding Grade |
| |
|
| |
Anchor Bolts: |
| |
Shall Be Made In Accordance With ASTM 36 |
| |
|
| |
Grout: |
| |
Grout Of 25-Mm Minimum Thickness Shall Be Provided For All Foundations Supporting Equipment, Columns And Structures With Base Plates. |
| |
|
| |
Construction Includes: |
| |
| |
|
 |
Concrete. |
 |
Excavation. |
 |
Fill. |
 |
Setting Out. |
 |
Grounding Inspection. |
 |
Backfill. |
 |
Anchor Bolts. |
 |
Grouting. |
|
| |
|
| |
Concrete Paving Design Includes: |
| |
| |
|
 |
General. |
 |
Drainage. |
 |
Base Course. |
 |
Vapor Barrier. |
 |
Expansion Joints. |
 |
Concrete Works. |
 |
Base Course. |
|
| |
|
| |
All Concrete Paving Shall Be Designed According To Section 3.0 Of This Specification And ACI 318. |
| |
| |
|
 |
Finish. |
|
| |
 |
Setting Out. |
|
| |
|
| |
The Work Shall Be Set Out And Constructed To Dimensions, Coordinates And Elevations Given On The Relevant Drawings. |
| |
|
| |
 |
Membranes. |
|
| |
|